Nerve Plexus Parameters
Right of centre: epithelial drag ($J_{drag}$). Basal cells steer growing tips and carry the fibres with them, which makes the plexus centripetal. Left of centre: nerve → epithelium template ($J_{ne}$). Basal cell polarity turns toward the local nerve fibres, so an earlier nerve whorl can seed the epithelial whorl (nerves release substance P, CGRP and NGF, which support epithelial migration). Centre: the two layers do not interact.
Growth cones follow neighbouring fibres, so the plexus forms long, roughly parallel bundles. Low values give a tangled, tortuous plexus.
Stromal nerves pierce Bowman's layer between this radius and the limbus (5.6 mm), each giving a leash of 2 to 4 subbasal fibres. 5.4 mm means limbal entry only.
Hypothetical attractant at the whorl. No such cue has been identified, so it is off by default.
Hypothetical imposed inferonasal push from blinking. Off by default, so any whorl is emergent.
Branching probability at segment ends and along shafts (NGF/GDNF dependent).
In developing mice the nerve whorl appears at about 3–4 weeks, but the epithelial whorl only at 4–8 weeks. Epithelial drag alone cannot explain that. Each option below lets the nerves form a whorl on their own. To let the epithelium follow the nerves, move the coupling slider above to the left of centre. All are off by default.
Growth cones turn the same way every time, because their filopodia rotate in one direction (Tamada et al. 2010). Positive values turn them clockwise, negative values anticlockwise. Together with any inward cue, this gives a spiral with no help from the epithelium.
On: each growth cone turns in the local tangent plane of the shape set under Corneal Geometry, its heading is carried along the surface (geodesic transport), and the turn is scaled by how much of the filopodial sweep touches the curved substrate. Off: the turn is applied in the flat top-down view, so the shape cannot affect it. Compare the two to see what the geometry does to a chiral nerve whorl.
Range over the cornea and all headings, relative to a flat substrate. Real filopodia are about 2–10 μm long. Longer values exaggerate curvature sensing.
Growth cones turn toward the cathode of an electric field (Song et al. 2004, corneal wounds). Here a field is assumed to converge on the corneal apex. It pulls nerves inward with no epithelial flow, but on its own it does not make a spiral.
A sideways push at right angles to the inward direction. This is the old electric or magnetic explanation for why most whorls turn clockwise (Dua et al. 1996). It acts at every radius around the apex, so it imposes a fixed handedness.
Quantitative IVCM Metrics
Soft Active Matter Mechanics & XYZ Hypothesis
Corneal epithelial maintenance follows $X + Y = Z$: where $X$ (limbal stem cell influx) plus $Y$ (basal proliferation) is balanced by $Z$ (superficial desquamation / loss at apex).
Cells are soft self-propelled discs (speed $v_0$ along polarity $\hat{\mathbf{p}}_i$) with pair repulsion $\mathbf{F}_{ij}$. Each polarity turns, with strength $J$, toward its neighbours' polarities and toward the direction the cell is actually being pushed (flocking). Nothing in the model is spiral-shaped or chiral: there is no guidance field, no built-in handedness and, by default, no chemotactic cue. Cells are pushed inward only by the crowding from limbal influx, and extrusion follows the same crowding law everywhere.
The cornea is topologically a disc, and inflow at the limbus forces the orientation field to carry a net +1 topological charge. Where the inward flux runs out near the centre, aligned cells cannot simply converge, so the +1 defect becomes a vortex, and a spiral whorl emerges. Clockwise and anticlockwise whorls are equally likely (spontaneous symmetry breaking). This follows the soft active matter model of Kostanjevec, Sknepnek, Collinson & Henkes (eLife RP 106061), which found the spiral is robust to corneal curvature but not to topology.
The sheet lives on a curved biconic corneal surface (Corneal Geometry panel). Cells touch in 3D, forces and motion stay within the sheet, and each polarity is carried across the surface as the cell moves. Curvature can therefore only act through geometry, unless one of the two hypothesis terms is switched on. Every +1 (whorl) and −1 (saddle) defect of the polarity field is detected and marked.
Subbasal Axonal Guidance & Whorl Morphogenesis
Stromal nerves pierce Bowman's layer, mostly in the mid-periphery and periphery. Each perforation gives rise to a leash of unmyelinated subbasal fibres that runs beneath the basal epithelium toward the centre, with Y-shaped branches.
No chemoattractant at the apex or whorl has been identified. In the default model, the centripetal course and the whorl both come from the centripetal migration of basal epithelial cells, which steer growth cones and carry existing fibres with them (epithelial drag $J_{drag}$). Fibres also grow along one another (fasciculation $J_{fas}$), which keeps them in long, near-parallel bundles. The nerve whorl therefore inherits whatever spiral the epithelium forms, and sits at the epithelial whorl rather than at the corneal apex. Whorl chemotaxis ($v_{chem}$) is an optional, hypothetical cue. The eyelid shear term ($\tau_{shear}$) is an optional, imposed rotation for testing that hypothesis. It is off by default, so any nerve whorl in the simulation comes from the epithelium alone.
Timing problem. In developing mice the subbasal nerve whorl is first seen at about 3–4 weeks after birth, but the basal epithelial whorl only at 4–8 weeks (reviewed by Marfurt et al. 2019). A whorl that is passively dragged into shape cannot appear before the one dragging it, so epithelial drag is not sufficient on its own. The Nerve-First Hypotheses panel adds the alternative explanations proposed in the literature:
- Growth-cone chirality ($\chi$). Growth-cone filopodia rotate right-screw, so neurites on a flat substrate turn clockwise with no external cue (Tamada et al. 2010, J Cell Biol; Heacock & Agranoff 1977). A steady turn on top of any inward cue traces a spiral, so the plexus builds its own whorl, with a preferred handedness. The turn is applied on the corneal shape selected under Corneal Geometry: in the local tangent plane, with the heading carried along the surface, and scaled by how much of the filopodial sweep touches the curved substrate (see Does corneal shape change a chiral whorl? below).
- Galvanotropism ($E_{gal}$). Growth cones turn toward the cathode in fields of about 10 mV/mm, and corneal nerve sprouting follows the endogenous field in vivo (Song et al. 2004, J Cell Sci). A field converging on the apex is assumed here. It has not been measured in the intact cornea.
- Tangential electromagnetic cue ($B_{tan}$). Marfurt et al. suggest that a tangential electric force or magnetic field, at right angles to centripetal migration, may bend fibres into a spiral near the apex. Static magnetic fields make cultured corneal epithelial cells form whorls (Dua et al. 1996, Eye). A fixed field cannot explain anticlockwise whorls or eyes with two opposing whorls.
- Nerve → epithelium template ($J_{ne}$). The coupling may run the other way. Corneal nerves release substance P, CGRP and NGF, which support epithelial proliferation and migration, so basal cells could orient along an earlier plexus. That would make the epithelial whorl follow the nerve whorl. It is the left half of the Nerve ↔ Epithelium Coupling slider, so it cannot be on at the same time as epithelial drag.
- A shared upstream cue (for example a common electric field acting on both layers on different timetables, as Marfurt et al. also propose) can be explored by combining $E_{gal}$ or $B_{tan}$ with the epithelial centripetal cue $F_{in}$.
The Whorl Onset readout records when each layer's signed spiral order first stays at or above 0.2, so you can check which whorl forms first. In the default model the nerves rarely lead. Nerve-First Whorl sets the coupling fully to nerve → epithelium, so there is no epithelial drag at all. Without drag the fibres need an inward cue that does not come from the epithelium, so the preset uses galvanotropism toward the apex (0.3) together with chirality (0.6). In 16 headless runs on the average human shape, the nerve whorl usually appeared after 4–5 simulated weeks (range 4–11). The epithelial whorl always came later, from a few days to about 6 months after it, and always with the same handedness. On the steep (57 D) shape the epithelium was slower: in 3 of 16 runs it had no whorl after a year.
Does corneal shape change a chiral whorl? With Turn on the selected corneal surface ticked, the corneal shape can act on a chiral growth cone in two ways. First, the turn and the heading live on the curved surface. A tip with no cue follows a geodesic of that shape, and astigmatism, decentration or a second apex bend those paths. Second, the turn is scaled by filopodial contact. A filopodium of length $L_f$ beside the growth cone sits $\kappa_n L_f^2/2$ above a convex substrate, so less of the sweep touches it. In headless runs (chirality 0.6, galvanotropism 0.3, no coupling, 16 runs per shape, about 140 days) the results were:
- Handedness and timing did not change. Every shape gave the same handedness. The nerve whorl appeared at 31–34 days on every shape. With no chirality, no shape produced a spiral on its own.
- Filopodial contact barely matters at real sizes. The corneal radius of curvature (about 5–8 mm) is about 1,000 times a growth cone. With $L_f$ = 8 μm, contact changes by under 1% on a normal or steep cornea. Spiral order changed by less than the run-to-run noise (0.489 vs 0.483 on the 57 D shape). Only an unrealistic 40 μm filopodium weakened the spiral clearly (0.36).
- Seen top-down, the whorl looks tighter on steeper corneas. Top-down spiral order was 0.41 on a flat disc, 0.45 on the average human shape and 0.48 on the 57 D shape. Measured on the surface itself it stayed at 0.39–0.41. The extra spiral seen in a frontal (IVCM-like) view therefore comes from foreshortening on the slope, not from stronger turning. The applied turn in the flat-view model is smaller than the same turn on the surface, so that model under-reads chirality on curved corneas.
Both readouts are shown under Nerve Spiral Order. Untick the surface option to repeat any run with the old flat-view turning.
Nerve ↔ Epithelium Coupling (Derived Drag Field)
The epithelial drag field is not prescribed: every frame it is coarse-grained from the velocities of the live epithelial cells (Gaussian kernel, 0.4 mm) and interpolated at each axon. It steers growing tips (weighted by $J_{drag}$ and by local flow speed) and drags the existing fibre shafts toward the whorl at a fraction $J_{drag}$ of the local epithelial velocity, with fibres tethered at the limbus. Changing any epithelial parameter therefore reshapes the plexus. One slider sets the direction. To the right of centre the coupling is epithelium → nerve (drag, the default at 0.45). To the left it is nerve → epithelium, through the template term $J_{ne}$: each basal cell's polarity turns toward the local fibre axis, weighted by how aligned and dense the fibres are. At the centre the layers do not interact. The two directions are never on together.
Epithelial Model Parameters
Rate of newly differentiated cells produced at the limbal rim.
Mitosis of Transient Amplifying cells within the cornea.
Crowding-dependent loss of mature epithelial cells, with the same rate law across the whole cornea.
Flocking strength: how fast each cell's polarity turns toward its neighbours' and its own motion. Not curvature, and not a spiral cue. Low $J$ gives disordered or jammed flow; above about 0.3 a whorl self-organises.
Hypothetical cue pointing at the limbal centre, off by default. The whorl forms without it. Strong values override the emergent vortex.
Number of color-coded clonal sectors along the limbus.
Two Whorls sets the shape and hypothesis terms too. Each apex holds a stable +1 defect, with a saddle between them. These defects are mainly convergent (aster-like), not strongly spiral. Without apex seeking, two whorls merge into one.
The failed stretch of limbus produces no new cells. You can also drag the white handles at either end of the rose arc on the canvas to set how much of the limbus fails, or drag the arc itself to move it.
Corneal Geometry
Keratometric power of the flat meridian, $K = 337.5/R_0$ (mm). 0 D is a flat disc, 43 D is a human cornea ($R_0$ 7.8 mm), 57 D is mouse-like and nearly hemispherical at this size.
$Q<0$ prolate (flattens toward the limbus; human about −0.26), $Q=0$ spherical, $Q>0$ oblate.
90° is vertical (with-the-rule), 0°/180° horizontal (against-the-rule).
Decentration of the apex from the limbal centre (+X right, +Y up).
A Gaussian bump added to the surface. Tall, narrow bumps create a second local high point.
Turns each cell's polarity uphill, toward the nearest local apex. An imposed cue, not a geometric effect.
Extra extrusion on the most elevated (most lid-exposed) epithelium.