Calibrates photographic brightness against reference points of known reflectance, then reports a hazy or scarred area's brightness relative to that calibration line.
Before you continue: confirm crossed polarising filters are fitted — one over your light source, one over the camera lens, rotated 90° to each other. Without this, surface glare will swamp the reading you're trying to measure.
✓Polarisers fitted and crossed (rotate one until glare/reflections are minimised in the viewfinder).
✓Camera exposure, ISO, focus, and white balance set manually — no auto modes.
✓Same darkened room and light position you plan to use every session.
✓Camera at the same distance and angle from the surface as previous sessions.
✓Subject as still as possible — the capture takes a short burst of frames.
Keep everything exactly as it was for the calibration photo. The calibration you just set only holds up if nothing changed in between.
✓Don't touch exposure, ISO, focus, or white balance — leave every setting where it was.
✓Keep the light and camera in the same position and angle.
✓Photograph the eye now, in the same session, before anything can drift.
Glare check: waiting for camera…
Captures 8 frames in quick succession, discards any that are blurred from motion, aligns the rest to correct for hand or eye movement between frames, and averages them to reduce noise. The glare check above is a rough guide to whether your polarisers are well crossed — it is not a measurement.
Area
Mean brightness
Raw value
Calibrated value
No measured areas yet.
How it works
What's actually measured. This is a calibrated photographic brightness tool, not a densitometer. It converts pixel brightness in a region of interest into a number on a scale anchored by reference standards of known reflectance — analogous in principle to reflection densitometry, not to Scheimpflug backscatter densitometry. Reflectance density (surface diffuse reflection) and corneal backscatter (volumetric tissue scattering) are different physical processes; this tool has not been validated against either clinical grading or Scheimpflug GSU, and its output should be read as a repeatable relative brightness index for one subject over time, not an absolute or clinically-equivalent density value.
Pipeline. Pixel values are first linearised (the sRGB gamma curve is inverted) so the maths operates on actual light intensity rather than display-encoded brightness. You can then choose a logarithmic scale (−log₁₀ of intensity, the convention printed reflectance standards use) or a linear scale (raw calibrated intensity, closer to the weak single-scattering approximation for corneal backscatter). These are two different ways of turning brightness into a number, not two routes to the same physical quantity — pick one and stay consistent across a session.
Calibration. Reference regions of known value are fit to measured brightness by least-squares regression (two points: exact fit; three or more: reported with R², a measure of how well the points agree with each other — a low R² flags inconsistent lighting, glare, or motion between shots, not a software error).
Separate calibration photo. If calibration is done on its own photo, it's only valid for a second photo taken under identical camera settings, illumination geometry, and working distance. Nothing in the pixel data lets the app verify this — it depends entirely on the acquisition protocol being followed.
Clipping. A ⚠ flags any region where over 5% of sampled pixels are at sensor saturation (0 or 255, 8-bit) — those pixels carry no usable intensity information and the reading should be treated as unreliable.
Scope. Crossed polarisation, manual exposure lock, and consistent illumination geometry (described before capture) matter more to data quality than anything computed here. No data is saved, exported, or transmitted — this is a personal longitudinal tracking aid, not a diagnostic device, and does not substitute for clinical examination or validated corneal imaging.